- ; Copyright Schneider & Koch & Co. Datensysteme GmbH 1991-1994
- ; EISA configuration file for SK-NET FDDI-FI
- ;
- ; 30-Mar-1994 Rev. 2.0
- ; Corrected IOs
- ; Marked IRQs non-shareable
- ;
- ; Contains resources for I/O, DMA, BootPROM, Interrupts.
- ; The suitable DIP switches must be set manually.
- ; CARD ENABLE is NOT executed!!!
- ;
-
- BOARD
- ID = "SKDF000"
- NAME = "SK-NET FDDI-FI LAN Interface Board"
- MFR = "Schneider & Koch GmbH"
- CATEGORY = "NET"
- SLOT = ISA16
- LENGTH = 330
- SKIRT = NO
- READID = NO
- ;? BUSMASTER = 15
- IOCHECK = INVALID
- DISABLE = UNSUPPORTED
- COMMENTS = "SK-NET FDDI-FI Board:\n
- product number 11-11-072 (70-00-018)"
-
- JUMPER(1) = 1
- NAME = "W1"
- JTYPE = PAIRED
- REVERSE = YES
- FACTORY = LOC(1) 1
- COMMENTS = "
- Different AT vendors make different usage of the SA17..SA19 address lines.
- If the pins are not connected, behavior is compatible with the original IBM AT.
- If the jumper connects the pins, it is compatible with most other PCs."
-
- SWITCH(1) = 8
- NAME = "W2"
- STYPE = DIP
- REVERSE = YES
- FACTORY = LOC(1-8) 00000000
- COMMENTS = "
- W2.1 - W2.3 set I/O Base Address\n
- W2.4 enable/disable Boot ROM Base Address\n
- W2.5 - W2.8 set Memory Base Address"
-
- SWITCH(2) = 8
- NAME = "W3"
- STYPE = DIP
- REVERSE = YES
- FACTORY = LOC(1-8) 00001100
- COMMENTS = "
- This switches determine the DMA channel"
-
- SWITCH(3) = 8
- NAME = "W4"
- STYPE = DIP
- REVERSE = YES
- FACTORY = LOC(1-8) 00000001
- COMMENTS = "
- This DIP switch sets the IRQ line"
-
- SOFTWARE(1) = "
- The current settings of your SK-NET FDDI-FI LAN Interface Board are:\n"
-
- FUNCTION = "FDDI Adapter"
- TYPE = "NET,FDDI"
- CONNECTION = "
- One connector: Class B board\n
- Two connectors: Class A board"
-
- SUBFUNCTION = "I/O Address"
- CHOICE = "0100h"
- LINK
- PORT = 0100h-010Fh
- INIT = SWITCH(1) LOC(1-3) 000
- INIT = SOFTWARE(1) "I/O Base = 0100h"
- CHOICE = "0120h"
- LINK
- PORT = 0120h-012Fh
- INIT = SWITCH(1) LOC(1-3) 001
- INIT = SOFTWARE(1) "I/O Base = 0120h"
- CHOICE = "0180h"
- LINK
- PORT = 0180h-018Fh
- INIT = SWITCH(1) LOC(1-3) 010
- INIT = SOFTWARE(1) "I/O Base = 0180h"
- CHOICE = "01A0h"
- LINK
- PORT = 01A0h-01AFh
- INIT = SWITCH(1) LOC(1-3) 011
- INIT = SOFTWARE(1) "I/O Base = 01A0h"
- CHOICE = "0220h"
- LINK
- PORT = 0220h-022Fh
- INIT = SWITCH(1) LOC(1-3) 100
- INIT = SOFTWARE(1) "I/O Base = 0220h"
- CHOICE = "0240h"
- LINK
- PORT = 0240h-024Fh
- INIT = SWITCH(1) LOC(1-3) 101
- INIT = SOFTWARE(1) "I/O Base = 0240h"
- CHOICE = "0320h"
- LINK
- PORT = 0320h-032Fh
- INIT = SWITCH(1) LOC(1-3) 110
- INIT = SOFTWARE(1) "I/O Base = 0320h"
- CHOICE = "0340h"
- LINK
- PORT = 0340h-034Fh
- INIT = SWITCH(1) LOC(1-3) 111
- INIT = SOFTWARE(1) "I/O Base = 0340h"
-
- SUBFUNCTION = "IRQ Line"
- CHOICE = "IRQ 9"
- LINK
- IRQ = 9
- SHARE = NO
- INIT = SWITCH(3) LOC(1-8) 00000001
- INIT = SOFTWARE(1) "IRQ 9"
- CHOICE = "IRQ 3"
- LINK
- IRQ = 3
- SHARE = NO
- INIT = SWITCH(3) LOC(1-8) 00001000
- INIT = SOFTWARE(1) "IRQ 3"
- CHOICE = "IRQ 4"
- LINK
- IRQ = 4
- SHARE = NO
- INIT = SWITCH(3) LOC(1-8) 00000100
- INIT = SOFTWARE(1) "IRQ 4"
- CHOICE = "IRQ 5"
- LINK
- IRQ = 5
- SHARE = NO
- INIT = SWITCH(3) LOC(1-8) 00000010
- INIT = SOFTWARE(1) "IRQ 5"
- CHOICE = "IRQ 10"
- LINK
- IRQ = 10
- SHARE = NO
- INIT = SWITCH(3) LOC(1-8) 00010000
- INIT = SOFTWARE(1) "IRQ 10"
- CHOICE = "IRQ 11"
- LINK
- IRQ = 11
- SHARE = NO
- INIT = SWITCH(3) LOC(1-8) 00100000
- INIT = SOFTWARE(1) "IRQ 11"
- CHOICE = "IRQ 12"
- LINK
- IRQ = 12
- SHARE = NO
- INIT = SWITCH(3) LOC(1-8) 01000000
- INIT = SOFTWARE(1) "IRQ 12"
- CHOICE = "IRQ 15"
- LINK
- IRQ = 15
- SHARE = NO
- INIT = SWITCH(3) LOC(1-8) 10000000
- INIT = SOFTWARE(1) "IRQ 15"
-
- SUBFUNCTION = "DMA Channel"
- CHOICE = "DMA 5"
- LINK
- DMA = 5
- SHARE = NO
- SIZE = WORD
- TIMING = DEFAULT
- INIT = SWITCH(2) LOC(1-8) 00001100
- INIT = SOFTWARE(1) "DMA Channel 5"
- CHOICE = "DMA 6"
- LINK
- DMA = 6
- SHARE = NO
- SIZE = WORD
- TIMING = DEFAULT
- INIT = SWITCH(2) LOC(1-8) 00110000
- INIT = SOFTWARE(1) "DMA Channel 6"
- CHOICE = "DMA 7"
- LINK
- DMA = 7
- SHARE = NO
- SIZE = WORD
- TIMING = DEFAULT
- INIT = SOFTWARE(1) "DMA Channel 7"
- CHOICE = "DMA 3"
- LINK
- DMA = 3
- SHARE = NO
- SIZE = WORD
- TIMING = DEFAULT
- INIT = SWITCH(2) LOC(1-8) 00000011
- INIT = SOFTWARE(1) "DMA Channel 3"
-
- SUBFUNCTION = "Boot PROM"
- CHOICE = "disable"
- LINK
- INIT = SWITCH(1) LOC(4) 0
- INIT = SOFTWARE(1) "Boot PROM disabled"
- CHOICE = "enable"
- LINK
- INIT = SWITCH(1) LOC(4) 1
- INIT = SOFTWARE(1) "Boot PROM enabled"
-
- SUBFUNCTION = "Boot PROM Start Address"
- CHOICE = "disabled"
- DISABLE = YES
- FREE
- INIT = SWITCH(1) LOC(5-8) 0000
- INIT = SOFTWARE(1) "Boot PROM disabled"
- CHOICE = "DC000"
- LINK
- MEMORY = 8K
- ADDRESS = 0DC000h
- INIT = SWITCH(1) LOC(5-8) 0001
- INIT = SOFTWARE(1) "Boot PROM at DC000h"
- CHOICE = "DA000"
- LINK
- MEMORY = 8K
- ADDRESS = 0DA000h
- INIT = SWITCH(1) LOC(5-8) 0010
- INIT = SOFTWARE(1) "Boot PROM at DA000h"
- CHOICE = "D8000"
- LINK
- MEMORY = 8K
- ADDRESS = 0D8000h
- INIT = SWITCH(1) LOC(5-8) 0011
- INIT = SOFTWARE(1) "Boot PROM at D8000h"
- CHOICE = "D6000"
- LINK
- MEMORY = 8K
- ADDRESS = 0D6000h
- INIT = SWITCH(1) LOC(5-8) 0100
- INIT = SOFTWARE(1) "Boot PROM at D6000h"
- CHOICE = "D4000"
- LINK
- MEMORY = 8K
- ADDRESS = 0D4000h
- INIT = SWITCH(1) LOC(5-8) 0101
- INIT = SOFTWARE(1) "Boot PROM at D4000h"
- CHOICE = "D2000"
- LINK
- MEMORY = 8K
- ADDRESS = 0D2000h
- INIT = SWITCH(1) LOC(5-8) 0110
- INIT = SOFTWARE(1) "Boot PROM at D2000h"
- CHOICE = "D0000"
- LINK
- MEMORY = 8K
- ADDRESS = 0D0000h
- INIT = SWITCH(1) LOC(5-8) 0111
- INIT = SOFTWARE(1) "Boot PROM at D0000h"
- CHOICE = "CE000"
- LINK
- MEMORY = 8K
- ADDRESS = 0CE000h
- INIT = SWITCH(1) LOC(5-8) 1000
- INIT = SOFTWARE(1) "Boot PROM at CE000h"
- CHOICE = "CC000"
- LINK
- MEMORY = 8K
- ADDRESS = 0CC000h
- INIT = SWITCH(1) LOC(5-8) 1001
- INIT = SOFTWARE(1) "Boot PROM at CC000h"
- CHOICE = "CA000"
- LINK
- MEMORY = 8K
- ADDRESS = 0CA000h
- INIT = SWITCH(1) LOC(5-8) 1010
- INIT = SOFTWARE(1) "Boot PROM at CA000h"
- CHOICE = "C8000"
- LINK
- MEMORY = 8K
- ADDRESS = 0C8000h
- INIT = SWITCH(1) LOC(5-8) 1011
- INIT = SOFTWARE(1) "Boot PROM at C8000h"
- CHOICE = "C6000"
- LINK
- MEMORY = 8K
- ADDRESS = 0C6000h
- INIT = SWITCH(1) LOC(5-8) 1100
- INIT = SOFTWARE(1) "Boot PROM at C6000h"
- CHOICE = "C4000"
- LINK
- MEMORY = 8K
- ADDRESS = 0C4000h
- INIT = SWITCH(1) LOC(5-8) 1101
- INIT = SOFTWARE(1) "Boot PROM at C4000h"
- CHOICE = "C2000"
- LINK
- MEMORY = 8K
- ADDRESS = 0C2000h
- INIT = SWITCH(1) LOC(5-8) 1110
- INIT = SOFTWARE(1) "Boot PROM at C2000h"
- CHOICE = "C0000"
- LINK
- MEMORY = 8K
- ADDRESS = 0C0000h
- INIT = SWITCH(1) LOC(5-8) 1111
- INIT = SOFTWARE(1) "Boot PROM at C0000h"
-
- SUBFUNCTION = "Usage of SA17..SA19"
- CHOICE = "Others"
- LINK
- INIT = JUMPER(1) LOC(1) 1
- INIT = SOFTWARE(1) "System drives SA17..SA19"
- CHOICE = "IBM AT Compatible"
- LINK
- INIT = JUMPER(1) LOC(1) 0
- INIT = SOFTWARE(1) "Board drives SA17..SA19"